The following are frequently asked questions latitude
information, to provide a reference to answer your questions.
Q : This product was come out for how long ?
Get a patent promotion has approximately seven years.
Q : Will the life of the product ?
About 6 to 7 years, there is no damage to the case. Improper use only one vendor in the silicone conveyor using CR Type (wheel), the distance between the surface of the measured object too tight, resulting in wear and tear, the surface has been proposed Touch to.
Q : Temperature detection of many types on the market, you differ? Why more expensive ?
It takes just a few aspects to talk about:
Common formula implantable probe / infrared temperature detector, whose accuracy is affected by the surrounding distance, temperature, humidity, .. will affect the data. And, because of the different detection principles, leading to different sensitivities. Common temperature measurement principle is as follows:
Thermocouple / thermistor / resistance temperature detector PT100 (RTD),

The vast majority of the resistance temperature detector (RTD), etc. made of platinum, nickel, or copper materials, through the composition of platinum or copper alloys were strictly controlled, It can make very precise resistivity. The CHW patent affixing Surface temperature detector system for the platinum resistor, precision DINIEC751 Ciass A or B, 200 ℃ / 2S reaction, platinum resistor is the most accurate of stable temperature sensor.
Q : Six circuit monitoring electrical input signal is translated into six groups INPUT, OUTPUT but why ?
Principles are a set of output signals output, while if remote display shall be installed at six I / O output card.
Q : Whether there will be long-distance power line impedance error value?
Pull the Sensor directly to a monitoring terminal (PVC or Teflon line) in the standard 100 meters, impedance and signal value is no different; if there is more than 100 meters above the ± 2 ~ 3 ° C temperature difference. (If the distance is too long, the proposed increase converter by the remote alarm monitoring software).
Q : When SENSOR attached to the high voltage electricity is high, it can withstand ?
SENSOR is attached to the thermal casing or housing (due to the insulating non-conductive), non-directly attached to the bronze medal (bare row), and designed to withstand the 5KV.
Q : SENSOR bad, whether repair ?
SENSOR is a consumable, bad connector at Taihuan by new can, without changes lines.
Q : CHW temperature detectors classification of many, how to choose for their own ?
Based on a variety of considerations to machinery and equipment industry diversification do not it, so in the design, particular distinction because of different sizes, different environments, different ways of joining, and has its appropriate temperature Sensor. ex:
CS1 Type: Applicable in a large surface area of ​​machinery and equipment, glass, metals, plastics, PE, PP, ABS, PET Jieke close.
CM Type: Applicable on any surface equipment, resistance to harsh environments and chemicals. Glass, metals, plastics, PE, PP, ABS, PET Jieke close.
CM1 Type: Applicable on any surface equipment, resistance to harsh environments and chemicals. Glass, metals, plastics, PE, PP, ABS, PET Jieke close.
CM2 Type: Applicable on any surface equipment, resistance to harsh environments and chemicals. Glass, metals, plastics, PE, PP, ABS, PET Jieke close.
CMS Type: Suitable for freezing, cold storage, communications room, indoor space temperature detection.
CB Type: Applicable to all types of tubular body surface temperature anomaly detection.
CB1 Type: Applicable to all types of tubular body surface temperature anomaly detection.
CR Type: For rubber, Teflon, silicone, metal and other heating rollers, conveyor belts, motor shaft and other temperature test.
Q : CHW Temperature monitoring alarm transmission Relay classified numerous, how to choose for their own ?
When the temperature detector selected is completed, please re-detect points of view and to select the appropriate installation method to monitor electrical translation. ex:
CH1S: Disk type - Temperature monitoring alarm transmission electric Translation (single-loop)
CH5S: Disk type - Temperature monitoring alarm transmission electric Translation (V circuit)
CH6S: Disk type - Temperature monitoring alarm transmission electric Translation (six-loop)
CH1S-B: The entire set of wall-mounted cabinet - Temperature monitoring alarm transmission electric Translation (single-loop)
CH5S-B: The entire set of wall-mounted cabinet - Temperature monitoring alarm transmission electric Translation (V circuit)
CH6S-B: The entire set of wall-mounted cabinet - Temperature monitoring alarm transmission electric Translation (six-loop)
CPC-1000: Orbital - Temperature monitoring alarm transmission electric Translation (single-loop)
CTR1: Aluminum Rail -RS485 signals into electrical translation (single-loop)
CTR2: Aluminum Rail -RS485 signals into electrical translation (two loops)
CTPC-6000: Chinese-touch automatic SMS alerts machines
CGL-3000: Temperature and humidity detection alarm transmitter
CBUS-485: Wire temperature transmitter detected